GEN III Circulator

Designed for practice, qualifying, and race conditions the Generation III Water Circulator efficiently cools hot race engines and removes air trapped in the system; allowing more runs per session. Optional heater available.

g3circulator g3circulator2

PART NUMBERS:

CR-NC-BOA001A………. 3rd Generation Water Circulator (with heater)
CR-NC-BOA002A………. 3rd Generation Water Circulator

  • Heavy duty front casters
  • Recessed control panels
  • Stainless steel pump (increased flow rate 20% – 10 psi added at pump exit)
  • Dump valve
  • Float valve
  • Filter to “catch” small pebbles, silicone, etc. – minimal flow loss
  • Heater control valve
  • 30 gallon tank capacity

Specifications

AMP Requirements (220V)
Pump: 3.6 amps
Fan: 1.7 amps
Heather: 16.3 amp
Flow Rates (flowmeter located at radiator exit -without engine and water pump)
25 ft lines: 10.3 gpm (will pump 5 gallons in 15.23 sec — exit of one 25 ft line)
GEN II : 8.5 gpm (will pump 5 gallons in 18.66 sec — exit of one 25 ft line)
40 ft lines : 9.8 gpm (will pump 5 gallons in 16.89 sec — exit of one 40 ft line)
GEN II : 7.9 gpm (will pump 5 gallons in 20.57 sec — exit of one 40 ft line)
Heat Cycles (diverter valve on “RAD ONLY” – control valve switched to “HEAT”)
Time (minutes)
GEN III Temp (Degrees F)
GEN II Temp (Degrees F)
0
78
80
5
91
87
10
107
94
15
113
97
20
119
103
25
124
107
30
128
112

graph

(diverter valve on “RAD ONLY” — control valve switched to “HEAT”)